Back to All Modules
Permits to Work

Confined Space Permit

Entry permits for permit-required confined spaces, with atmospheric test readings, named entry supervisor, attendant and entrants, and rescue arrangements confirmed before anyone goes in.

What is Confined Space Permit?

Confined spaces kill workers every year, and too often the second fatality is the coworker who went in after the first. Tanks, manholes, vaults, pits, silos: the hazard is usually one you can't see or smell. SiteChief's confined space permit follows the entry permit requirements of 29 CFR 1910.146 for general industry and 29 CFR 1926 Subpart AA for construction, so nobody enters a permit-required confined space until the conditions on the permit have been met and the entry supervisor has signed.

Before entry, the permit records the atmospheric testing: oxygen first, then flammable gases and vapors, then toxics, each reading logged against the acceptable entry conditions you set (typically 19.5% to 23.5% oxygen, below 10% of the LEL, and below the PEL for contaminants such as hydrogen sulfide and carbon monoxide). It names the tester, the instrument and the time. Periodic or continuous monitoring requirements are written into the permit, along with ventilation and purging, and if a reading goes out of range the entry supervisor cancels the permit and the entrants come out.

The permit also makes you answer the rescue question before the work starts, not during the emergency. Who is the rescue service, have they been evaluated and told about this entry, what retrieval equipment is at the opening, and how does the attendant summon help? With that on the permit, and the attendant holding a current list of who is inside, the attendant stays outside and calls it in. Canceled permits are kept on file for the annual program review.

Regulatory Compliance

  • • 29 CFR 1910.146 - Permit-Required Confined Spaces (general industry)
  • • 29 CFR 1926 Subpart AA - Confined Spaces in Construction (1926.1200-1213)
  • • 29 CFR 1910.146(k) and 1926.1211 - Rescue and emergency services
  • • ISO 45001:2018 Clause 8.2 - Emergency preparedness and response
Confined Space Permit Checklist
Confined space inventory with permit-required and non-permit classification
Pre-entry atmospheric testing record: oxygen, flammable gas and toxic readings
Periodic and continuous monitoring requirements with alarm set points
Rescue plan record covering the rescue service, retrieval equipment and personnel
Entrant sign-in and sign-out log kept by the attendant
Emergency contacts with one-tap calling

Key Benefits

No entry until the permit conditions are met and the entry supervisor has signed

Atmospheric test readings recorded with tester, instrument and time

Rescue arrangements confirmed up front, so the attendant calls for help and stays out

Rescue service and emergency numbers on the permit, one tap from the attendant's phone

Entry supervisor, attendant and authorized entrants named on every permit

Entry and exit log shows exactly who is inside the space at any moment

Features & Capabilities

Confined space inventory with permit-required and non-permit classification

Pre-entry atmospheric testing record: oxygen, flammable gas and toxic readings

Periodic and continuous monitoring requirements with alarm set points

Rescue plan record covering the rescue service, retrieval equipment and personnel

Entrant sign-in and sign-out log kept by the attendant

Emergency contacts with one-tap calling

Isolation, lockout, ventilation and purging requirements

Permit cancellation and close-out, with canceled permits retained for review

How It Works

1

Identify the space, classify it, and decide whether the job can be done without entry

2

Isolate and ventilate the space, then test the atmosphere with a calibrated, bump-tested monitor

3

Confirm the rescue service, retrieval equipment and the attendant's means of calling for help

4

Entry supervisor signs the permit, setting monitoring, ventilation and duration

5

Attendant logs entrants in and out and keeps contact until the permit is canceled

Frequently asked questions

What is Confined Space Permit?
Entry permits for permit-required confined spaces, with atmospheric test readings, named entry supervisor, attendant and entrants, and rescue arrangements confirmed before anyone goes in.
How does Confined Space Permit work?
Identify the space, classify it, and decide whether the job can be done without entry. Isolate and ventilate the space, then test the atmosphere with a calibrated, bump-tested monitor. Confirm the rescue service, retrieval equipment and the attendant's means of calling for help. Entry supervisor signs the permit, setting monitoring, ventilation and duration. Attendant logs entrants in and out and keeps contact until the permit is canceled.
What are the main benefits of Confined Space Permit?
No entry until the permit conditions are met and the entry supervisor has signed. Atmospheric test readings recorded with tester, instrument and time. Rescue arrangements confirmed up front, so the attendant calls for help and stays out. Rescue service and emergency numbers on the permit, one tap from the attendant's phone.
Which regulations does Confined Space Permit help you comply with?
29 CFR 1910.146 - Permit-Required Confined Spaces (general industry). 29 CFR 1926 Subpart AA - Confined Spaces in Construction (1926.1200-1213). 29 CFR 1910.146(k) and 1926.1211 - Rescue and emergency services. ISO 45001:2018 Clause 8.2 - Emergency preparedness and response.

Ready to Use Confined Space Permit?

Start managing your health and safety with our comprehensive solution.

30-day free trial · Cancel anytime