Back to All Modules
Risk & HazCom

HazCom & SDS Management

Hazard communication software built around the safety data sheet: chemical inventory, GHS pictograms and signal words, SDS access for employees, and exposure controls checked against PELs.

What is HazCom & SDS Management?

Walk into most plants or jobsite trailers and the HazCom program looks the same. A yellow binder of safety data sheets, half of them superseded. A chemical list last updated two purchasing managers ago. A spray bottle of something blue on the dock with no label on it. Hazard Communication, 29 CFR 1910.1200, has sat near the top of OSHA's most-cited standards for years, and it's rarely because nobody cared. The paperwork just can't keep up with what comes through receiving. This module starts from the SDS. Upload it and the hazard classification, pictograms, signal word, first aid measures and exposure limits are pulled out for you, so you're not retyping sections 2, 4 and 8 by hand and transposing a figure.

From there you build the chemical inventory your written program has to include under 1910.1200(e): each product, where it's stored, how much is on hand, and the current SDS attached. Employees can pull up any sheet on a phone during their shift, which is what paragraph (g)(8) means by readily accessible. A locked office at 2 a.m. doesn't count. The GHS pictograms and signal word sit on the record too, so a supervisor can check a secondary container label against the shipped one in a few seconds. HazCom training at initial assignment, and again when a new chemical hazard comes into the work area, goes on each person's training record. When the compliance officer picks a name off the floor and asks to see it, you have it.

Knowing what's in the drum is half the job. The other half is exposure. For each task you record who's exposed and by which route, whether that's inhalation, skin contact or ingestion, and compare the work against the PELs in 1910.1000 and the limits the manufacturer lists in section 8. Controls go in the order OSHA expects: substitute if you can, enclose or ventilate if you can't, then administrative controls, and respirators or other PPE last. Where a substance-specific standard calls for medical surveillance, such as hexavalent chromium, lead or respirable crystalline silica, the assessment flags it before first exposure. Review dates follow the risk, and an incident, a process change or a new air monitoring result brings the review forward.

Regulatory Compliance

  • • 29 CFR 1910.1200 Hazard Communication (written program, labels, SDS, training)
  • • 29 CFR 1910.1000 Air Contaminants (permissible exposure limits)
  • • 29 CFR 1926.59 Hazard Communication in construction
  • • 29 CFR 1910.134 Respiratory Protection
  • • ISO 45001 (control of hazardous substances)
HazCom & SDS Management Checklist
Safety data sheet upload with automatic extraction of hazard classification, first aid and section 8...
Chemical inventory with storage location and quantity on hand, linked to the current SDS
GHS pictograms, signal words and hazard statements shown on each chemical record
Exposure assessment covering inhalation, skin contact and ingestion, compared against PELs
Control selection following the hierarchy of controls, from substitution through to PPE
PPE and respirator requirements linked to the PPE module, with stock alerts

Key Benefits

A chemical inventory built from the SDSs you hold today, with storage location and quantity for every product

Hazard data lifted straight from the sheet, so fewer transcription errors in exposure limits and hazard statements

Current SDSs available to employees on a phone during every shift, as 1910.1200(g)(8) requires

GHS pictograms and signal words on every chemical record, ready to check against container labels

Controls recorded in hierarchy order, with engineering and administrative controls considered before PPE

Medical surveillance flagged at assessment stage where a substance-specific OSHA standard may apply

Features & Capabilities

Safety data sheet upload with automatic extraction of hazard classification, first aid and section 8 exposure data

Chemical inventory with storage location and quantity on hand, linked to the current SDS

GHS pictograms, signal words and hazard statements shown on each chemical record

Exposure assessment covering inhalation, skin contact and ingestion, compared against PELs

Control selection following the hierarchy of controls, from substitution through to PPE

PPE and respirator requirements linked to the PPE module, with stock alerts

HazCom training logged on each employee's training record

Review dates set by substance risk, brought forward when the work or the monitoring results change

How It Works

1

Upload the SDS, or key the chemical in by hand if the supplier's sheet is unusable

2

Check the extracted hazard classification, pictograms, signal word and exposure limits

3

Add the product to the chemical inventory with its storage location and quantity

4

Record who's exposed and by which route, then pick controls in hierarchy order

5

Flag medical surveillance where the substance calls for it and set the review date

Frequently asked questions

What is HazCom & SDS Management?
Hazard communication software built around the safety data sheet: chemical inventory, GHS pictograms and signal words, SDS access for employees, and exposure controls checked against PELs.
How does HazCom & SDS Management work?
Upload the SDS, or key the chemical in by hand if the supplier's sheet is unusable. Check the extracted hazard classification, pictograms, signal word and exposure limits. Add the product to the chemical inventory with its storage location and quantity. Record who's exposed and by which route, then pick controls in hierarchy order. Flag medical surveillance where the substance calls for it and set the review date.
What are the main benefits of HazCom & SDS Management?
A chemical inventory built from the SDSs you hold today, with storage location and quantity for every product. Hazard data lifted straight from the sheet, so fewer transcription errors in exposure limits and hazard statements. Current SDSs available to employees on a phone during every shift, as 1910.1200(g)(8) requires. GHS pictograms and signal words on every chemical record, ready to check against container labels.
Which regulations does HazCom & SDS Management help you comply with?
29 CFR 1910.1200 Hazard Communication (written program, labels, SDS, training). 29 CFR 1910.1000 Air Contaminants (permissible exposure limits). 29 CFR 1926.59 Hazard Communication in construction. 29 CFR 1910.134 Respiratory Protection. ISO 45001 (control of hazardous substances).

Ready to Use HazCom & SDS Management?

Start managing your health and safety with our comprehensive solution.

30-day free trial · Cancel anytime

We use cookies. Essential ones are on. Optional ones need your OK.